Superalloy Maximum Service Temperature, applied to Nimonic 80A (N07080): verified numbers first, then the reasoning a specifier applies to Nimonic 80A. A RAS Thermal reference page on superalloy maximum service temperature.
Nimonic 80A (N07080) is a Nimonic alloy rated to 815 °C, stocked for Automotive exhaust valves.
As a chemistry anchor from the verified composition tables, Inconel 718 spans Ni 50.0-55.0%, Cr 17.0-21.0%, Mo 2.80-3.30% and Nb 4.75-5.50%, and Hastelloy C-276 spans Mo 15.0-17.0%, Cr 14.5-16.5%, Fe 4.0-7.0% and W 3.0-4.5%.
What Superalloy Maximum Service Temperature means for Nimonic 80A
Nimonic 80A (N07080) on superalloy maximum service temperature: density 8.19 g/cm³, verified ceiling 815 °C. The deciding facts are temperature, media and form, and they land on exhaust valves, turbine blades and high-temperature springs to 815 °C.
| Property | Nimonic 80A |
|---|---|
| Grade | Nimonic 80A (N07080) · GB GH4080A |
| Density | 8.19 g/cm³ |
| Max service temp | 815 °C |
| Best duty | Exhaust valves, turbine blades and high-temperature springs to 815 °C |
| Available forms | Forging, Wire, Spring Wire, Flange, Bar & Rod, Plate & Sheet |
| Standards | ASTM B637, BS HR 201, AMS 5763, DIN 17742 |
Specification signals
Nimonic 80A is rated to 815 °C. That ceiling is verified, and it is the number the datasheet and the certificate must both hold. The documented applications tell the same story (automotive exhaust valves, marine diesel engine valves), and a duty outside that list deserves a second look before Nimonic 80A goes on the order.
- One Nimonic 80A datasheet callout does most of the work on this page: 815°C service temperature. A purchasing audit on the Nimonic 80A order checks that line first.
In practice
Above the line, the grade is out of specification. Below it, the alloy family and the media decide the rest. The ceiling decides.
How to select the right option for your process
Work through these checks in order so the component stays inside its specification:
- Step 1: Confirm the maximum service temperature. Fix the peak continuous service temperature the component will see. It decides whether a precipitation-hardened grade such as Inconel 718 (rated 650 °C) or an oxidation-resistant solid-solution grade such as Hastelloy X (rated 1100 °C) is even in the running.
- Step 2: Match the environment and alloy family. Identify the corroding or oxidizing media (chlorides, acids, seawater, combustion gas) and match the family: Ni-Cr-Mo for wet corrosion, Ni-Cu for seawater and hydrofluoric acid, cobalt-base for wear and biocompatibility, precision grades for controlled physical properties.
- Step 3: Choose the product form. Select the semi-finished form: bar and rod (Ø6-350 mm), plate and sheet (0.5-80 mm), strip (0.05-3.0 mm), pipe and tube (OD 6-219 mm), wire (Ø0.10-12.0 mm) or a forged ring, disc or shaft from 5 kg to 3,000 kg.
- Step 4: Set the dimensions and tolerances. State the finished dimensions, condition (hot rolled, cold drawn, solution annealed, spring temper) and surface finish against the form’s stock range, so the mill certificate matches the drawing.
- Step 5: State the standard and certificate. Declare the governing ASTM / AMS / GB/T standard and the certification level: EN 10204 3.1 with heat-specific chemistry, or 3.2 third-party witnessed. The grade is proven by the mill test certificate, not assumed.
Frequently Asked Questions (FAQ)
How does superalloy maximum service temperature resolve for Nimonic 80A?
Heat decides first. Margin has a price.
What is Nimonic 80A best used for?
Nimonic 80A is stocked for exhaust valves, turbine blades and high-temperature springs to 815 °C; the documented edge is that the classic gamma-prime strengthened valve alloy, serviceable to 815 °C with good hot hardness.
What forms is Nimonic 80A available in?
Stocked forms: Forging, Wire, Spring Wire, Flange, Bar & Rod, Plate & Sheet.
What standards does Nimonic 80A meet?
ASTM B637, BS HR 201, AMS 5763, DIN 17742 are the standards Nimonic 80A is supplied against, each order closed by an EN 10204 3.1 mill test certificate.
When does Nimonic 80A stop being the right choice?
Two things end it: a peak service temperature above 815 °C, or media outside the family Nimonic 80A was built for.